New Step by Step Map For high performance liquid chromatography
New Step by Step Map For high performance liquid chromatography
Blog Article
크로마토그래피 원리의 큰 틀도 마찬가지로 두 상에 대한 분배 차이를 이용하여 분석물을 분리, 정제할 수 있습니다. 다만 크로마토그래피에서 두 개의 상은 하나는 고정하고 다른 하나는 일정 방향으로 이동시켜 사용합니다.
This gentle handed throughout the ingredient and absorbed by it. On other conclusion There exists a detector to identify what is missing during the UV lights. The quantity of UV absorbed is dependent upon the amount of element passing out in the column.
物質の濃度により光の通過する角度が変わることを利用した検出器。原理上グラジェント分析はできない(グラジェントによって移動相自体の屈折率が変化するため)。また、感度が低いのが欠点だが、大部分の物質に対して使用できる。
The selection to start with acetonitrile is arbitrary—we will just as quickly choose to begin with methanol or with tetrahydrofuran.
物質にエネルギーを与える(励起)ことにより発光する(蛍光)性質を利用した検出器。一般に選択性が高く高感度で、物質に特異的な検出が可能。蛍光する性質を持たない物質については、その物質を標識することにより検出が可能になる。
シリカゲルの粒子径が小さければ小さいほどピークの分離性は良くなるが、送液に必要なポンプの圧力が高くなる。そのため、ポンプ-インジェクター間、インジェクター-カラム間の配管の耐圧を上げたり、カラム自体を比較的高温の下にさらして溶媒の粘度を下げ、抵抗を小さくする工夫をしている。
It is accustomed to separate the cations and ions. Solute ions as well as the stationary phase inside the column have their charge. If the charges amid them are reverse, They may be retained in the column, which is more eluted.
Acid–foundation chemistry isn't the only example of a secondary equilibrium reaction. Other examples contain ion-pairing, complexation, as well as conversation of solutes with micelles. We'll look at the past of such in Chapter 12.seven here whenever we focus on micellar electrokinetic capillary chromatography.
Differing kinds of detectors Employed in HPLC are refractive index detectors, UV detectors, and fluorimetry detectors.
Broadened peaks can obscure focus on peaks and make quantification tough. Here are some common results in and alternatives for peak broadening:
Measurement-exclusion chromatography, also referred to as gel filtration or gel permeation chromatography, separates substances based on their measurement and molecular weight. Scaled-down molecules can penetrate the porous framework of the stationary section and elute a lot quicker, even though larger sized molecules are held for a longer period.
Widespread mobile period modifiers like acids and bases could be extra to good-tune the conversation involving analytes plus the column. These modifiers can:
The elution purchase of solutes in HPLC is governed by polarity. For a traditional-phase separation, a solute of decrease polarity spends proportionally a lot less time inside the polar stationary read more section and elutes prior to a solute that's more polar. Supplied a particular stationary stage, retention times in normal-period HPLC are managed by modifying the cellular section’s Qualities. Such as, If your resolution involving two solutes is bad, switching to your less polar mobile stage retains the solutes on the column for a longer time and supplies more possibility for his or her separation.
The injector introduces a precise quantity in the sample Answer into your cell section stream. A number of injection solutions exist, with loop injection staying a common system.